Appendix A: OptiLogic Technical Specifications Pointe Controller User Guide
272
To configure Output Status, click the to the right and select a tag from
the pop-up menu. Each tag can be used only once.
Max Value – The maximum value of the range in which the output will
be ON. When the counter value is above this maximum, the output will be
OFF. Mapped to any 32-bit Signed tag (%IX, %MX, or %QX).
To configure Max Value, click the
to the right and select a tag from the
pop-up menu. Each tag can be used only once.
Min Value – The minimum value of the range in which the output will be
ON. When the counter value is below this minimum, the output will be
OFF. Mapped to any 32-bit Signed tag (%IX, %MX, or %QX).
To configure Min Value, click the
to the right and select a tag from the
pop-up menu. Each tag can be used only once.
When you have finished configuring the module, click OK to save your changes
and close the window.